Medical Incineraotors

Medical Incineraotors

This incinerator with “PYROLYTIC” combustion must have: 
1. A combustion chamber of waste: 
o Perfectly tight door for the manual loading of waste. The loading should be Manual, Batch Load 
o A burner of lighting which the use is limited to the ignition of waste. 
o Frontage of loading with door seals gone up on hinges, wheel of screw plug, flexible joint, and stuffing insulating out of refractory. 
o The insulation of the combustion chamber should be composed of refractory bricks, having a high content of aluminium and insulates bricks in order to assure a minimum temperature on the outside sheet metal.
o  Composition of the refractory;

Refractory concrete :
. Thickness : ≥100 mm
. Nature: 42% of Al203
Insulate in fibrous panels :
Thickness: ≥75 mm
Nature: Calcium silicate.
Burner of lighting of waste, with fuel, standard mono-bloc casting guiding  plunging flame, lighting and safety of electronic ignition, permanent ventilation, electromagnetic sluice gate of regulation and isolating valve. 
Plate of combustion in Carborundum, avoiding the fixing of glass and slags

2.20
A chamber of post combustion of gases 
o A burner of combustion of gases, 
o A device of injection of air allowing a total recombustion of gases, 
o A device of air inlet of cooling of waste gases, 
o A sheath of evacuation of the gases burnt. 
o Carcass in strong sheet steel with support of connection. 
o Composition of the refractory;
Refractory concrete :
Thickness : ≥150 mm
Nature: 65% of Al203
Insulate in fibrous panel :
Thickness: ≥85 mm
 Nature: Calcium
o Burner with fuel, mono-bloc casting guiding type with horizontal flame, lighting and safety of electronic ignition, permanent ventilation, electromagnetic sluice gate of regulation and isolating valve. 
o A secondary injection of air to ensure perfect oxygen content. 

2.21
A control box ensuring the complete cycle of combustion. 
2.22
Fan: 
o Electro-ventilator distributing the secondary air, the regulation of the air flow being carried out by valves and following the control of the automatic cycle. 
Controls and regulations: 
Control box watertight to dust, including: 

A switch circuit breaker for each engine (ventilators and burners). 
A timer with adjustable temporization for the regulation of each burner. 
A regulator with digital watching for the temperature of combustion. 
A regulator with digital watching for the temperature of post combustion. 
Electric box

2.23
The secondary combustion chamber must destroy the contaminant product and must resist to high temperature(1100 °C)

2.24 Process Filtering system: Scruber to be mentionned as optional
2.25 Emission Standards Compliance: BS 3316 or équivalent standard
2.26
Capacity to treat Plastic: Not less than 40% by weight
2.27 CE Manufacturing Compliance: BS EN 746-2-1997
2.28
Bidder must give batches of spare parts of first urgency and consumable of the incinerator.

2.29
The installed incinerator must bear a one year guarantee.
2.30
The supplier shall perform an onsite installation of the incinerator.