biohazard waste disposal guidelines
biohazard waste disposal guidelines 1. The ground should be flat when install the incinerator. There should be 100cm at least between the incinerator and the walls on the two sides and the back, which is in convenient maintenance and repair. 2. A), Place the incinerator main body(combustion chamber) and fixed with bolts and Asbestos tape. B), Place the wet scrubber system and fixed with bolts and Asbestos tape. C). Install chimneys and fixed with bolts, Asbestos tape and Steel Rope. D). Fix the incineration house roof. E). Fix burner, blower, wind tube, electric system, fuel system. 3. Check the electric wire: the incinerator’s electric circuit should be linked with the ground wire to guard against current leakage. The link-up of the electric wire should be checked carefully before starting the incinerator, in case of wrong link-up or leakage. 4. Check of the fuel supply system: Except the Burner’s soft pipe which is used for the fuel flowing-in and flowing-back, all the rest pipes must use brass or steel pipe. No leakage is allowed at pipe junctions. Any leakage should be blocked in time. 5. Install steel rope with the chimney, to avoid tilt by wind. 6. Install net cover at the blower, to avoid sundries. 7. If the fuel is Natural Gas with gas burner, please contact with local administration section and install gas supplier system. 8. Crane or forklift is necessary when download/upload/install incinerator. 9. Topped work house roof after installation. 10.Get the video material: http://www.eclover.net/category/incinerator-video/ Nanjing Clover Medical Technology Co.,Ltd. incinerate china orders incinerators hospital waste disposal ppt safe waste incinerator company medical sharps disposal services in kenya Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) Burn Rate (Average) 10-20 kg/hour 20-30 kg/hour 30-50 kg/hour 50-100 kg/hour Control Mode PLC Auto. PLC Auto. PLC Auto. PLC Auto. […]
Read MoreClinical waste incineration and hazardous waste incineration facility
- Comments Off on Clinical waste incineration and hazardous waste incineration facility
- Mar, 02, 2021
- hiclover
- eblogs
Clinical waste incineration and hazardous waste incineration facility Model YD-50C Picture Brand/Code HICLOVER/N1004 Burning Rate (kgs/Hour) Average 50 kgs/Hour Feed Capacity (kgs) Average 80 kgs/feeding Equipment Weight 2500 kgs Primary Chamber (Liters) 400 Secondary Chamber (Liters) 140 External Dimensions (cm) 180x160x200 Internal Dimensions (cm) 70x70x85 Oil Tank(Liters) 150 Door Opening (cm) 45×55 Chimney (M) 5 […]
Read MoreAnimal Cremation Incinerator Model A600
Phone: +86-13813931455(whatsapp/wechat)Website: http://www.hiclover.com/ Email: [email protected]: [email protected] Nanjing Clover Medical Technology Co.,Ltd. Model A600 Picture Feed Capacity Average 30 kgs per feeding(animal) Burning Rate Average 10 kgs per hour(animal) Voltage 220V Power 0.59Kw Fuel Natural Gas or Diesel oil or LPG Gas Burner Italy Burner Feed Mode Manual Feeding Fuel consumption (Oil) 10.0-16.0 Kgs/Hour Fuel consumption (Gas) 10.0-15.0m3/Hour External Dimensions 175 x 100 x […]
Read MoreES Fiber Production Line and 400mm Melt blown Production Line and 1600mm Melt blown Production Line and and N95 Mask Machine and Disposable Mask Machine
- Comments Off on ES Fiber Production Line and 400mm Melt blown Production Line and 1600mm Melt blown Production Line and and N95 Mask Machine and Disposable Mask Machine
- Apr, 20, 2020
- hiclover
- eblogs
1. N95 and Disposable Mask Machine 2. 400mm and 1600mm Melt blown Production Line 3. ES Fiber Production Line N95 Face Mask Machine Production Line Melt blown Production Line A.)Optional Capacity: 1600mm Efficiency: 95-97% FOB Term Price: USD per set Price Valid: 5days. Ave.60 Days ready for shipping. In stock […]
Read MoreN95 Face Mask Machine Production Line on Sale Now! $250,000USD per set
- Comments Off on N95 Face Mask Machine Production Line on Sale Now! $250,000USD per set
- Apr, 10, 2020
- hiclover
- eblogs
N95 Face Mask Machine Production Line on Sale Now! $250,000USD per set N95 Face Mask Machine Production Line on Sale Now! $250,000USD per set l Dimension(L*W*H): 1037*855*1780 l Power Supply 15.3kw mono phase l Net Weight: approx.: 1500kg HICLOVER – Medical Environmental WWW.HICLOVER.COM Waste Incinerators Medical Waste Incinerator Pet Animal Cremation Solid Waste Incinerator Tel: +86-25-8461 0201 Mobile: +86-13813931455(whatsapp/wechat)Website: www.hiclover.com Email: [email protected]: [email protected] Nanjing Clover Medical Technology Co.,Ltd. […]
Read MoreFFP2 Breathing mask machine
Zhangjiagang Tengxiang Machinery Co., Ltd. Mobile: 0086-13962221749(whatsapp) Wechat: chncheumg Email: [email protected] Face Mask Machine for Coronavirus Disease COVID-19 平面口罩机参数: Semi-Automatic Mask Machine l Power supply: 3.3KW mono phase l Mask Size: 175mm*80-100mm (two or three layers) l Nonwoven (GMS): 10-50g l Capacity: 120 to 150pcs/min l Dimension(L*W*H):3800mm*500mm*1400mm l Net Weight: about 1000kg 焊接机参数: Welding Machine l Capacity: 5 to 10pcs/min l Power supply: 8.5KW mono phase […]
Read MoreSPECIAL COMBUSTION CHAMBER
* The combustion chamber of incinerator should adequate capacity to handle a consignment of 100-120 kg of hospital and medical waste. * The inside of combustion chamber should be a rectangular shape. * The size of the waste charging door should be 60 x 70 cm in order to well introduce waste into the combustion chamber. * The first phase of the incineration should be a combustion without air comparable to a gasification. * The combustion in a reduced atmosphere produces a combustion gas rich in CO and not in C02. This is a considerable advantage for the post-combustion of gases – CO is combustible. The process runs in a complete self-combustion and doesn’t need any other combustible, except for the preheating or the starting, if waste has a lower calorific power (L.C.P) to 1,500 kcal/kg. * The lack of air in this first phase allows to accept a heterogeneous calorific power of waste (1,000 to 6000 kcal/kg) without the risk of thermal overloading of the furnace, the energy recuperation equipment and the post-combustion chamber. This creates a supplementary security for the treatment of waste having variable calorific power from one delivery to another. This allows a loading in bulk without any sorting and mixing. * The combustion chamber is in thick sheet steel (4 to 8 mm) especially elaborated. * The insulation of the combustion chamber should composed of refractory bricks having high content aluminum and isolation bricks in order to assure a minimum temperature on the outside sheet metal.
Read MoreSPECIAL COMBUSTION CHAMBER
* The combustion chamber of incinerator should adequate capacity to handle a consignment of 100-120 kg of hospital and medical waste. * The inside of combustion chamber should be a rectangular shape. * The size of the waste charging door should be 60 x 70 cm in order to well introduce waste into the combustion chamber. * The first phase of the incineration should be a combustion without air comparable to a gasification. * The combustion in a reduced atmosphere produces a combustion gas rich in CO and not in C02. This is a considerable advantage for the post-combustion of gases – CO is combustible. The process runs in a complete self-combustion and doesn’t need any other combustible, except for the preheating or the starting, if waste has a lower calorific power (L.C.P) to 1,500 kcal/kg. * The lack of air in this first phase allows to accept a heterogeneous calorific power of waste (1,000 to 6000 kcal/kg) without the risk of thermal overloading of the furnace, the energy recuperation equipment and the post-combustion chamber. This creates a supplementary security for the treatment of waste having variable calorific power from one delivery to another. This allows a loading in bulk without any sorting and mixing. * The combustion chamber is in thick sheet steel (4 to 8 mm) especially elaborated. * The insulation of the combustion chamber should composed of refractory bricks having high content aluminum and isolation bricks in order to assure a minimum temperature on the outside sheet metal.
Read Morehospital waste management Incinerator system
Incinerator (hospital waste management system) is a turn-key project which will comprise a hospital grade incinerator, allied accessories and operation for proper disposal of hospital General medical waste (plastics, gloves and papers) and Infectious waste (blood-soaked bandages, sharps waste, surgical waste, human or body parts, cultures, and swabs).the unit should be of high performance to operated continuously for at-least 12 hours daily. Energy/Fuel Source for incinerator will be Natural Gas based on Pyrolysis with smokeless emission, for ensuring the clean environment system should strictly comply with Environmental Protection Agency (EPA) Pakistan emission standards. Technical Specifications: 1. Burning Capacity i. Incinerator should be capable to burn waste @ 100 kg / hr in single loading. 2. Construction i. Packaged type skid mounted dual chamber construction ii. Stainless steel or Mild steel outer with thickness 5mm or more, sheet should be painted with heat resistant and anti-corrosive paint. iii. Internal surface of incinerator should be line with non– cracking refractory bricks made of ceramics or concrete to withstand the temperature of 1400 oC, furthermore bricks must be backed by thermal insulation and have thickness in between 220C250 mm. iv. There should be thermal insulation of high performance calcium silicate (Density 230Kg.m-3)to withstand high temperature with flame spread/smoke index not more than 1. v. Refractory and thermal insulation must be designed in robust way so that outer temperature on sheet does not rise above 55– 60 oC even after continuous operation of 12 hours. 3. Primary Chamber i. […]
Read Morehospital waste management Incinerator system
Incinerator (hospital waste management system) is a turn-key project which will comprise a hospital grade incinerator, allied accessories and operation for proper disposal of hospital General medical waste (plastics, gloves and papers) and Infectious waste (blood-soaked bandages, sharps waste, surgical waste, human or body parts, cultures, and swabs).the unit should be of high performance to operated continuously for at-least 12 hours daily. Energy/Fuel Source for incinerator will be Natural Gas based on Pyrolysis with smokeless emission, for ensuring the clean environment system should strictly comply with Environmental Protection Agency (EPA) Pakistan emission standards. Technical Specifications: 1. Burning Capacity i. Incinerator should be capable to burn waste @ 100 kg / hr in single loading. 2. Construction i. Packaged type skid mounted dual chamber construction ii. Stainless steel or Mild steel outer with thickness 5mm or more, sheet should be painted with heat resistant and anti-corrosive paint. iii. Internal surface of incinerator should be line with non– cracking refractory bricks made of ceramics or concrete to withstand the temperature of 1400 oC, furthermore bricks must be backed by thermal insulation and have thickness in between 220C250 mm. iv. There should be thermal insulation of high performance calcium silicate (Density 230Kg.m-3)to withstand high temperature with flame spread/smoke index not more than 1. v. Refractory and thermal insulation must be designed in robust way so that outer temperature on sheet does not rise above 55– 60 oC even after continuous operation of 12 hours. 3. Primary Chamber i. […]
Read MoreRecent Posts
- biohazard waste disposal guidelines
- Clinical waste incineration and hazardous waste incineration facility
- Animal Cremation Incinerator Model A600
- ES Fiber Production Line and 400mm Melt blown Production Line and 1600mm Melt blown Production Line and and N95 Mask Machine and Disposable Mask Machine
- N95 Face Mask Machine Production Line on Sale Now! $250,000USD per set