incinerator control box, fan, burner
19. A control box ensuring the complete cycle of combustion.
20. Fan:
Electro-ventilator distributing the secondary air, the regulation of the air flow being carried out by valves and
following the control of the automatic cycle.
21. Controls and regulations:
Control box watertight to dust, including:
A switch circuit breaker for each engine (ventilators and burners).
A timer with adjustable temporization for the regulation of each burner.
A regulator with digital watching for the temperature of combustion.
A regulator with digital watching for the temperature of post-combustion.
Electric box.
22. The de-ashing must be done in the bottom of the combustion chamber or the de-ashing should be automatic or manual batch
de-ashing.
23. Process filtering system: scrubber to be mentioned as optional
24. Emission standards compliance: BS 3316 or equivalent standard
25. Capacity to treat plastic: not less than 40% by weight